|
NewswireTODAY - /newswire/ -
Santa Barbara, CA, United States, 2009/02/27 - Wyatt Technology Corporation, the world leader in instruments for absolute macromolecular characterization, will unveil its brand new Dynamic Light Scattering (DLS) instrument - the DynaPro NanoStar - on booth #4386 at Pittcon 2009.
|
|
The Wyatt NanoStar is an all-new DLS designed to deliver optimum versatility and stability -- with more than twice the signal-to-noise of its predecessors-- to ensure consistently high performance.
With emphasis on innovation, the new Wyatt NanoStar surpasses the performance of conventional batch DLS instruments with a wealth of features, including a dedicated Static Light Scattering detector so it can measure not only hydrodynamic radii but also absolute molecular weights. The new instrument also has a TCP/IP interface, to allow it to be added to a laboratory network instantly and operated from anywhere with an Internet connection.
The temperature control built-in provides fast response times and wide temperature range (from 4C to 150C). The Nanostar offers the most precise temperature control ever available in batch DLS, with a stability of better than 0.01C over the entire range, and a proprietary thermal design that can change temperatures as quickly as 15C/min. When operating below ambient temperatures, the NanoStar employs a dual valve dry nitrogen flow that keeps the cell dry and dust free.
Its air-launched laser, coupled with proprietary optics for higher sensitivity, make single mode optical fiber technology obsolete. The NanoStar's multi-mode fibers collect a larger fraction of the scattered light, which gives better performance for weakly scattering samples. With higher sensitivity, the NanoStar also detects trace amounts of aggregation that other DLS instruments may miss.
A double density correlator is standard, which has 512 bins from 100 nsec to 1 hour, and instead of having 16 bins in the first stage and 8 in each subsequent stage, the NanoStar has 32 in the first stage and 16 in the higher stages. In order to ensure that the NanoStar never goes out of range, it comes equipped with automatic attenuation over five orders of magnitude.
Non-perturbing and non-destructive, the NanoStar determines the hydrodynamic radius and absolute molecular weight of nanoparticles simultaneously. With this information, the NanoStar provides unique insights beyond those obtained from conventional DLS technologies, opening new frontiers for any organization. The NanoStar can also be coupled with Wyatt's on-line multi-angle light scattering systems (DAWN and miniDAWN) for enhanced resolution of HPLC eluents.
About Wyatt
Based in Santa Barbara, California, Wyatt Technology (wyatt.com) is the world's leading provider of instruments for absolute macromolecular characterization. With over 40 years' experience developing multi-angle light scattering detectors, working with customers in the biotechnology, chemical, petrochemical, pharmaceutical, academic and government arenas, Wyatt prides itself on its entrepreneurial spirit, and the uniqueness of its offerings. The Company's groundbreaking technology and uncompromising levels of customer care make Wyatt the global hallmark in its field.
For further press information please contact: Laura Browne, The Scott Partnership, 1, Whiteside, Station Road, Holmes Chapel, Cheshire, CW4 8AA, United Kingdom T: +44 1477 539539 F: +44 1477 539540 - E: wyatt[.]scottpr.com
|