PRTODAY / NewswireToday Free press release distribution service network

Agency / Source: The Scott Partnership

This article was published free of charge. Only PREMIUM Articles are (Google AdSense™) 3rd party Ads-Free!

Thermo Fisher Scientific Develops New Method to Eliminate High Boiling Matrix Contamination - Thermo Fisher Scientific develops new method to eliminate high boiling matrix contamination in GC and GC/MS analyses of pesticides in food (NYSE: TMO)
Thermo Fisher Scientific Develops New Method to Eliminate High Boiling Matrix Contamination

 

NewswireToday - /newswire/ - Austin, TX, United States, 08/02/2010 - Thermo Fisher Scientific develops new method to eliminate high boiling matrix contamination in GC and GC/MS analyses of pesticides in food (NYSE: TMO).

   
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Medical Services/Equipment Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Thermo Fisher Scientific, Inc., the world leader in serving science, today announced a new method to effectively eliminate invisible high boiling matrices in the analysis of pesticides in food. Incorporating a programmable temperature vaporizing (PTV) injector, the Thermo Scientific TRACE GC Ultra GC/MS analyzer achieves sensitive, fast and reliable analysis of pesticides in low fat food products, significantly enhancing the productivity and efficiency of gas chromatography (GC) and gas chromatography mass spectrometry (GC/MS) systems for analyzing pesticides in food, while eradicating high boiling matrix. The new method is detailed in an application note, entitled "Eliminate Invisible High Boiling Matrix in GC and GC/MS by Using PTV Backflush Injection Technique for Increased Productivity and Reliability," which is available to download.

Pesticide extraction in low-fat food products, such as fruits and vegetables, normally results in high concentrations of lipid components as a matrix of high boiling compounds in the extracts. Once injected into a GC or GC/MS analyzer, high boiling substances accumulate on the analytical column of the system, contaminating it and causing an increasingly high background level. As high boiling compounds cannot be seen, there is no possibility of visual quality control. Bake-out procedures have been traditionally used, but these methods increase time between samples, are inefficient and reduce the column lifetime. An optimum solution would be the separation of the analytes from all high-boiling matrix material directly after injection.

The new application from Thermo Fisher demonstrates that a PTV injector with a pre-column and a carrier gas backflush capability offers a powerful method for separating analytes from high-boiling compounds. Following sample extraction using the QuEChERS technique, a PTV injector was used to inject the extract into the Thermo Scientific TRACE GC Ultra GC/MS analyzer. Pesticides travelled quickly into the system's analytical column whereas high boilers were kept in the pre-column that was swept backwards concurrently during the analytical run. As a result, the analytes transferred to the column and eluting to the MS source were free from high molecular weight compounds. Experimental results demonstrated that the PTV-GC/MS system can be used for both regular and large volume injections with numerous productivity advantages, including increased sensitivity, time and cost savings, easy maintenance, increased column lifetime and higher robustness of the entire analytical system.

For more information about the Thermo Fisher Scientific GC&GC/MS solutions, please call +1 800-532-4752, E: analyze[.]thermofisher.com.

Thermo Scientific is part of Thermo Fisher Scientific, the world leader in serving science.

About Thermo Fisher Scientific
Thermo Fisher Scientific, Inc. (thermoscientific.com) is the world leader in serving science. Our mission is to enable our customers to make the world healthier, cleaner and safer. With revenues of more than $10 billion, we have approximately 35,000 employees and serve customers within pharmaceutical and biotech companies, hospitals and clinical diagnostic labs, universities, research institutions and government agencies, as well as in environmental and process control industries. We create value for our key stakeholders through two premier brands, Thermo Scientific and Fisher Scientific, which offer a unique combination of continuous technology development and the most convenient purchasing options. Our products and services help accelerate the pace of scientific discovery, and solve analytical challenges ranging from complex research to routine testing to field applications.

 
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Medical Services/Equipment Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Agency / Source: The Scott Partnership

 
 

Availability: All Regions (Including Int'l)

 

Traffic Booster: [/] Quick Newswire Today Visibility Checker

 

Distribution / Indexing: [+]

 
 
# # #
 
 
  Your Banner Ad showing on ALL
Medical Services/Equipment articles,
CATCH Visitors via Your Competitors Announcements!


Thermo Fisher Scientific Develops New Method to Eliminate High Boiling Matrix Contamination

Non-featured company website links are shown on a random basis
It is OK to republish and/or LINK any newswire for any legitimate media purpose as long as you name Newswire Today and LINK as the source.
 
  For more information, please visit:
Links are available on a random basis for non premium members
|
Contact: Celine Callender - Scottpr.com 
+44 1477 539539 thermo[.]scottpr.com
 
Newswire Today - PRZOOM / PRTODAY disclaims any content contained in this article. If you need/wish to contact the company who published the current release, you will need to contact them - NOT us. Issuers of articles are solely responsible for the accuracy of their content. Our complete disclaimer appears here.
IMPORTANT INFORMATION: Issuance, publication or distribution of this press release in certain jurisdictions could be subject to restrictions. The recipient of this press release is responsible for using this press release and the information herein in accordance with the applicable rules and regulations in the particular jurisdiction. This press release does not constitute an offer or an offering to acquire or subscribe for any The Scott Partnership securities in any jurisdiction including any other companies listed or named in this release.

Medical Services/Equipment via RSS
AddThis press release: Thermo Fisher Scientific Develops New Method to Eliminate High Boiling Matrix ContaminationAdd Medical Services/Equipment News to My MSNAdd Medical Services/Equipment News to My Yahoo!Add NewswireToday Medical Services/Equipment Press Release Headline News to Your Google homepage or Google ReaderAdd NewswireToday - PRZOOM Headline News to FeedBurner Twitter /NewswireToday

This article was published free of charge. Only PREMIUM Articles are (Google AdSense™) 3rd party Ads-Free!


Read Latest Articles From The Scott Partnership / Company Profile



Molecular Profiles Invests £9 million in New Facility to Increase Manufacturing Capabilities
PRECOS to Unveil New Pre-clinical Oncology Service Portfolio
Wyatt Technology Employed to Develop Alternative Materials to Faulty Silicone Breast Implants
SmartKem Accelerates Pace in Asian Market by Signing Agreements with Asian Corporations
Analytical Technology Expands Team to Increase Capacity as Contract Wins Are Secured
Markes International Launches New CIA Advantage for Canister Analysis of Air Toxics
Optibrium and Cresset Announce Technology Collaboration
Novozymes Expands Collaboration with Upperton Limited to Offer Customers New Albumin Conjugation Solution
Thermo Fisher Scientific Names Winner of 2012 Winter Conference Award in Plasma Spectrochemistry
Thermo Fisher Scientific Showcases Solutions for Biobanks and Biorepositories at ESBB
Analytical Technology Awarded Prestigious Framework Agreement with Yorkshire Water
Optibrium Expands StarDrop Availability with Apple Mac Compatibility
Thermo Fisher Introduces New Informatics Solution for Water and Environmental Testing Laboratories
Cheshire B2B Agency the Scott Partnership Announces Second Acquisition in Two Months
Thermo Fisher Scientific Announces New Method for Precise and Reliable Analysis of Oil

Reserve This Permanent SPACE

Your LOGO permanently HERE on Newswire Today most visited Page start at $295 per month

 
Sponsored Links


Visit  Pickerel Lake Recovery Treatment Center

Visit  BizJobs.com










 
  ©2012 Newswire Today — Limelon Advertising, Co.
Home | About | Advertise | Contact | Investors | Sitemap | FRANCAIS
newswire, PR free press releases distribution magazines engine news alert newsroom press room breaking news public relations articles company news alerts blogsIt younews.me newswiredistribution ezine younews.asia bizentrepreneur biznewstoday digital business report market search pr firms agencies reports distri- bution today investor relation successful internet entrepreneur free newswire distribution prtoday.com freenewswiredistribution asianewstoday bizwiretoday USA pr UK today
 
PRTODAY & NewswireTODAY are NOT affiliated with USA TODAY (usatoday.com)