Virtual Facility Simulation Methodology Improves Exhaust Recirculation in Data Center - Simulating a data center enabled Cisco Systems to optimize cooling and efficiency
Virtual Facility Simulation Methodology Improves Exhaust Recirculation in Data Center

 

NewswireToday - /newswire/ - Lexington, MA, United States, 12/16/2009 - Simulating a data center enabled Cisco Systems to optimize cooling and efficiency.

   
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Data Content Management/Archiving Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Cisco Systems achieved an estimated saving of $120,000 per year in energy costs by simulating a data center using Future Facilities’ Virtual Facility (VF) simulation methodology. The simulation results were used to guide the placement of floor grilles and blanking panels that lowered information technology (IT) equipment inlet temperatures, making it possible to raise the chilled water setpoint by 8 degrees F. “The Virtual Facility is the best tool I've seen to tie together cooling, availability and efficiency in one analytic model,” said Rob Aldrich, Cisco Principal, Energy Efficiency.

A data center on Cisco’s San Jose campus occupies 7,000 square feet and is filled with 3202 units of IT equipment, drawing 770 kW. There is 1 MW of total power available and 820 kW of cooling capacity. The total energy bill for the facility was originally $1.4 million per year, including $660,000 per year in cooling energy costs and $707,000 per year in IT equipment energy costs. The facility has been in operation since 1999 with limited considerations for efficient operations.

A team led by Chris Noland, Engineering Manager for Cisco, employed two techniques in parallel to improve energy efficiency. This first was a familiar set of best practices that include blanking panels and plastic curtains to prevent mixing of supply and return air. Note was taken by Noland’s team of two major limitations of best practices. Firstly, best practices offer no foresight of outcome and Noland wanted a return on investment estimate in advance to justify the required expenditure. Secondly, best practices are designed to address room-level efficiency issues. In most data centers, efficiency problems are more likely to be caused by thermal incompatibilities between IT equipment and cabinets than they are by flawed room designs.

The second technique used was the VF simulation-based approach. The VF is a detailed, 3D model that can simulate the space, power and cooling behavior of the actual facility, including the thermal interactions between the room infrastructure, cooling system, cabinets and individual units of IT equipment. Throughout the life cycle, from initial design, construction, commissioning, to day-to-day operations, the VF can replace inadequate rules-of-thumb with scientific precision to manage resilience and efficiency of the mission critical facility.

The VF analysis showed clearly that exhaust recirculation within cabinets was the pressing problem, which was causing high IT equipment inlet temperatures and the need to overcool the chilled water system. Noland found that blanking and containment curtains actually increased inlet temperatures for many units of equipment in Lab 7D. The VF was used to guide the tactical placement of floor grilles and blanking panels that eliminated the worst of the cabinet and room-level hot spots.

The resulting 8 degrees Fincrease in chilled water set point provided a 30% reduction in power required for cooling and $120,000 per year in energy cost savings. There was no decrease in equipment resilience as determined by inlet air temperature. Based on the success of this application, Cisco Systems has adopted the VF approach to maximize resilience and efficiency over time.

For more information, contact Sherman Ikemoto, General Manager, Future Facilities Inc., P: 408-436-7701 or 408-497-3671.

 
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Data Content Management/Archiving Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Agency / Source: Structured Information

 
 

Availability: All Regions (Including Int'l)

 

Traffic Booster: [/] Quick Newswire Today Visibility Checker

 

Distribution / Indexing: [+]

 
 
# # #
 
 
  Your Banner Ad showing on ALL
Data Content Management/Archiving articles,
CATCH Visitors via Your Competitors Announcements!


Virtual Facility Simulation Methodology Improves Exhaust Recirculation in Data Center

Non-featured company website links are shown on a random basis
It is OK to republish and/or LINK any newswire for any legitimate media purpose as long as you name Newswire Today and LINK as the source.
 
  For more information, please visit:
Links are available on a random basis for non premium members
|
Contact: Steve Glad 
248-666-4177 sherman.ikemoto[.]futurefacilities.com
 
Newswire Today - PRZOOM / PRTODAY disclaims any content contained in this article. If you need/wish to contact the company who published the current release, you will need to contact them - NOT us. Issuers of articles are solely responsible for the accuracy of their content. Our complete disclaimer appears here.
IMPORTANT INFORMATION: Issuance, publication or distribution of this press release in certain jurisdictions could be subject to restrictions. The recipient of this press release is responsible for using this press release and the information herein in accordance with the applicable rules and regulations in the particular jurisdiction. This press release does not constitute an offer or an offering to acquire or subscribe for any Structured Information securities in any jurisdiction including any other companies listed or named in this release.

Data Content Management/Archiving via RSS
AddThis press release: Virtual Facility Simulation Methodology Improves Exhaust Recirculation in Data CenterAdd Data Content Management/Archiving News to My MSNAdd Data Content Management/Archiving News to My Yahoo!Add NewswireToday Data Content Management/Archiving Press Release Headline News to Your Google homepage or Google ReaderAdd NewswireToday - PRZOOM Headline News to FeedBurner Twitter /NewswireToday

This article was published free of charge. Only PREMIUM Articles are (Google AdSense™) 3rd party Ads-Free!


Read Latest Articles From Structured Information / Company Profile



SDP Introduces New Series of 1 mm Pitch Timing Belt Pulleys Designed for Miniature Applications
New Plastic Four-Bolt Flange Mounting Blocks with Insert Ball Bearings from QBC
Advanced Antivibration Components Introduces New Silicone Gel Bushings - Effective for Isolating Electronic Equipment
NVision Now Providing Product Defect Analysis
NVision Specialized Training Assists Navy’s Reverse Engineering
Beanstalk Loyalty Integrates Point-of-Sale Terminal with Social Media
3DScanCo to Resell Low-Cost, Portable Artec™, Creaform and 3Shape Laser Scanners
NVision Helps Soft Air Produce Handgun Replica Three Months Faster
PDI Releases 400 Amp Powerwave Bus System™
Fluke’s 'Glossary of Vibration Terms' Now Available Online - Fluke.com
IFPUG Approved for the Japan Industrial Standard
Beanstalk Data and XPIENT Launch Breakthrough Loyalty Marketing Platform
Fluke’s 'Vibration Testing and Mechanical Maintenance' Video Seminar Now Available Online
The International Function Point Users Group Announces Formal Relationship with TM Forum
RF Code and Future Facilities Form Partnership to Integrate Data Center Monitoring & Simulation

Reserve This Permanent SPACE

Your LOGO permanently HERE on Newswire Today most visited Page start at $295 per month

 
Sponsored Links


Visit  JobsWare.com

Visit  Pickerel Lake Recovery Treatment Center










 
  ©2012 Newswire Today — Limelon Advertising, Co.
Home | About | Advertise | Contact | Investors | Sitemap | FRANCAIS
newswire, PR free press releases distribution magazines engine news alert newsroom press room breaking news public relations articles company news alerts blogsIt younews.me newswiredistribution ezine younews.asia bizentrepreneur biznewstoday digital business report market search pr firms agencies reports distri- bution today investor relation successful internet entrepreneur free newswire distribution prtoday.com freenewswiredistribution asianewstoday bizwiretoday USA pr UK today
 
PRTODAY & NewswireTODAY are NOT affiliated with USA TODAY (usatoday.com)