PRTODAY / NewswireToday Free press release distribution service network

Agency / Source: The Scott Partnership

This article was published free of charge. Only PREMIUM Articles are (Google AdSense™) 3rd party Ads-Free!

Analytical Technology Launches AutoTest D12 Gas Monitor - Analytical Technology launches AutoTest D12 gas monitor for accurate toxic and combustible gas detection in water industry
Analytical Technology Launches AutoTest D12 Gas Monitor

 

NewswireToday - /newswire/ - Holmes Chapel, Cheshire, United Kingdom, 11/13/2008 - Analytical Technology launches AutoTest D12 gas monitor for accurate toxic and combustible gas detection in water industry.

   
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics/Instrumentation/RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Specialist electrochemical sensor manufacturer Analytical Technology announces the availability of its D12 2-wire loop powered Toxic/Combustible Gas Detector, a unique sensor which can provide the water and wastewater treatment industry with accurate and reliable readings of over 30 gas concentrations. The monitor is unique because every day the sensor is verified with a gas sample produced on demand. This AutoTest feature removes the need for manual checking and gives the D12 the lowest cost of ownership of any gas detector.

Water and wastewater treatment processes regularly require the use of toxic gases and chemicals which need constant monitoring and detection to ensure safety in the plant environment. The D12 Toxic / Combustible Gas Detector can efficiently monitor gas quantities within the installation area using smart electrochemical gas diffusion sensors. The innovative device is easily installed, operated and maintained, with clear menu-driven set up pages and a large LCD numerical display so gas values can be easily read along with alarm indication.

The D12 utilises Analytical Technology's Smart sensors. All calibration and AutoTest data is held within the memory of the sensor. If a new sensor is needed it arrives ready calibrated and all that is needed is to plug it in:
the D12 does the rest.

The Auto Test self-checking sensor system generates a small sample of gas every 24 hours to verify operation, ensuring accurate response checks. The detector uses an electrochemical sensor for toxic gases and a catalytic bead for combustible gases, which offer accuracy levels of ±10% of value. The monitor can be used in hazardous conditions, including outdoors and in high winds, while still giving reliable data.

Operation of the monitor is non-intrusive and calibration, alarm, set up options and data view are all accessible via a magnetic tool and can also be done remotely using a bench transmitter. The generators store run time information, such as sensor condition, gas type, range and calibration data using an internal logger, which can be accessed at anytime on the display. Data can be downloaded using the MOBUS protocol and is also compatible with HART communication output.

For further press information please contact: Eleanor CallanMonk, The Scott Partnership, 1 Whiteside, Station Road, Holmes Chapel, Cheshire, United Kingdom T: +44 (0)1477 539539 F: +44 (0)1477 539540 E: ati[.]scottpr.com.

 
 


Rank or share this free Newswire Press Release Distribution content. Join the network! Learn How!


Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics/Instrumentation/RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour.


 

Agency / Source: The Scott Partnership

 
 

Availability: All Regions (Including Int'l)

 

Traffic Booster: [/] Quick Newswire Today Visibility Checker

 

Distribution / Indexing: [+]

 
 
# # #
 
 
  Your Banner Ad showing on ALL
Electronics/Instrumentation/RFID articles,
CATCH Visitors via Your Competitors Announcements!


Analytical Technology Launches AutoTest D12 Gas Monitor

Non-featured company website links are shown on a random basis
It is OK to republish and/or LINK any newswire for any legitimate media purpose as long as you name Newswire Today and LINK as the source.
 
  For more information, please visit:
Links are available on a random basis for non premium members
|
Contact: Eleanor CallanMonk 
+44 (0)1457 832800 sales[.]atiuk.com
 
Newswire Today - PRZOOM / PRTODAY disclaims any content contained in this article. If you need/wish to contact the company who published the current release, you will need to contact them - NOT us. Issuers of articles are solely responsible for the accuracy of their content. Our complete disclaimer appears here.
IMPORTANT INFORMATION: Issuance, publication or distribution of this press release in certain jurisdictions could be subject to restrictions. The recipient of this press release is responsible for using this press release and the information herein in accordance with the applicable rules and regulations in the particular jurisdiction. This press release does not constitute an offer or an offering to acquire or subscribe for any The Scott Partnership securities in any jurisdiction including any other companies listed or named in this release.

Electronics/Instrumentation/RFID via RSS
AddThis press release: Analytical Technology Launches AutoTest D12 Gas MonitorAdd Electronics/Instrumentation/RFID News to My MSNAdd Electronics/Instrumentation/RFID News to My Yahoo!Add NewswireToday Electronics/Instrumentation/RFID Press Release Headline News to Your Google homepage or Google ReaderAdd NewswireToday - PRZOOM Headline News to FeedBurner Twitter /NewswireToday

This article was published free of charge. Only PREMIUM Articles are (Google AdSense™) 3rd party Ads-Free!


Read Latest Articles From The Scott Partnership / Company Profile



Molecular Profiles Invests £9 million in New Facility to Increase Manufacturing Capabilities
PRECOS to Unveil New Pre-clinical Oncology Service Portfolio
Wyatt Technology Employed to Develop Alternative Materials to Faulty Silicone Breast Implants
SmartKem Accelerates Pace in Asian Market by Signing Agreements with Asian Corporations
Analytical Technology Expands Team to Increase Capacity as Contract Wins Are Secured
Markes International Launches New CIA Advantage for Canister Analysis of Air Toxics
Optibrium and Cresset Announce Technology Collaboration
Novozymes Expands Collaboration with Upperton Limited to Offer Customers New Albumin Conjugation Solution
Thermo Fisher Scientific Names Winner of 2012 Winter Conference Award in Plasma Spectrochemistry
Thermo Fisher Scientific Showcases Solutions for Biobanks and Biorepositories at ESBB
Analytical Technology Awarded Prestigious Framework Agreement with Yorkshire Water
Optibrium Expands StarDrop Availability with Apple Mac Compatibility
Thermo Fisher Introduces New Informatics Solution for Water and Environmental Testing Laboratories
Cheshire B2B Agency the Scott Partnership Announces Second Acquisition in Two Months
Thermo Fisher Scientific Announces New Method for Precise and Reliable Analysis of Oil

Reserve This Permanent SPACE

Your LOGO permanently HERE on Newswire Today most visited Page start at $295 per month

 
Sponsored Links


Visit  Koncept Analytics

Visit  JobsWare.com










 
  ©2012 Newswire Today — Limelon Advertising, Co.
Home | About | Advertise | Contact | Investors | Sitemap | FRANCAIS
newswire, PR free press releases distribution magazines engine news alert newsroom press room breaking news public relations articles company news alerts blogsIt younews.me newswiredistribution ezine younews.asia bizentrepreneur biznewstoday digital business report market search pr firms agencies reports distri- bution today investor relation successful internet entrepreneur free newswire distribution prtoday.com freenewswiredistribution asianewstoday bizwiretoday USA pr UK today
 
PRTODAY & NewswireTODAY are NOT affiliated with USA TODAY (usatoday.com)