PRTODAY / NewswireToday Free press release distribution service network

Written by / Agency / Source: Bruker Corporation

Check Ads Availability|e-mail Article


Are you the owner of this article?, Turn it PREMIUM with your LOGO instead - and make it 3rd party Ads-Free! within the next hour!

World’s Highest Field 21 Tesla Magnet for FT-ICR Mass Spectrometry Installed at National High Magnetic Field Laboratory (NHMFL) - Bruker Corporation and the National High Magnetic Field Laboratory (NHMFL) at Florida State University (FSU) announced the successful installation of the world’s first 21 Tesla (T) magnet for Fourier Transform Ion Cyclotron Resonance (FT-ICR) - Bruker.com
World’s Highest Field 21 Tesla Magnet for FT-ICR Mass Spectrometry Installed at National High Magnetic Field Laboratory (NHMFL)

 

NewswireToday - /newswire/ - Billerica, MA, United States, 2014/06/16 - Bruker Corporation and the National High Magnetic Field Laboratory (NHMFL) at Florida State University (FSU) announced the successful installation of the world’s first 21 Tesla (T) magnet for Fourier Transform Ion Cyclotron Resonance (FT-ICR) - Bruker.com. NASDAQ: BRKR

   
 
Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics/Instrumentation/RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour. Learn How!


 

The installation represents the world’s highest field, persistent, superconducting magnet suitable for FT-ICR mass spectrometry, which is also often referred to as FTMS. The 21T magnet was designed and built by Bruker in collaboration with NHMFL scientists, and will be used in the NHMFL FT-ICR program in a project funded by the National Science Foundation, which makes cutting edge FT-ICR technologies available to the larger community of scientists.

FT-ICR is by far the highest resolution mass spectrometry technique available, and is useful in the analysis of extremely complex mixtures, including applications in petroleomics, dissolved organic matter (DOM), metabolomics, top-down proteomics, and MALDI imaging. The performance of FT-ICR systems improves with increasing magnetic field, and the 21T magnet is expected to enable further dramatic improvements in mass resolution, mass accuracy and dynamic range compared to the previous highest field of 15T. The ICR Program at the NHMFL is a world leader in instrument and technique development, as well as the pursuit for novel applications of FT-ICR mass spectrometry.

Professor Alan Marshall, the Robert O. Lawton Professor of Chemistry and Biochemistry at Florida State University and Director of the High Field FT-ICR program at the NHMFL, commented: “We are delighted to report that the 21T Bruker magnet is at full field. The other subsystems of the 21T FT-ICR mass spectrometer have been designed and are currently being assembled, for availability targeted for early fall of 2014.”

Professor Marshall added: “Three primary science drivers for this instrument are: (a) faster throughput without loss of mass resolution for top-down proteomics; (b) extension of the size and complexity of protein complexes whose contact surfaces are mapped by solution-phase hydrogen/deuterium exchange, and © improved mass resolution and dynamic range for characterizing compositionally complex organic mixtures (petroleum, dissolved organic matter, metabolome). The higher magnetic field should result in dramatic improvement (by factors of 40-100%) in FT-ICR MS figures of merit, including mass resolution and resolving power, mass accuracy, dynamic range, and data acquisition speed.”

The 21 T magnet design offers a 110 mm room temperature horizontal bore, with fringe field profiles and room temperature bore access optimized for FT-ICR MS. It includes many design features pioneered by Bruker, including operation at ~2 Kelvin by use of Bruker’s unique UltraStabilized™ sub-cooling technology, the UltraShield™ technology to reduce stray fields, as well as novel active magnet refrigeration technology that virtually eliminates cryogen refills and user maintenance of the magnet. In addition to FTMS, the 21T magnet is also suitable for ultra-high field preclinical MRI for highest sensitivity and resolution in mouse neuroimaging.

Dr. Gerhard Roth, the Bruker Ultra-High Field Magnet Manager, said: “The 21T FT-ICR magnet is based on the wealth of experience gathered in ultra-high field magnet technology for NMR and for MRI magnets. Bruker is extremely pleased to supply this cutting-edge 21T magnet to enable new scientific research directions in ultra-high field FT-ICR mass spectrometry.”

About Bruker Corporation

Bruker (bruker.com) is a leading provider of high-performance scientific instruments and solutions for molecular and materials research, as well as for industrial, diagnostics and applied analysis.

Investor Contact: Joshua Young, Vice President of Investor Relations
Bruker Corporation
T: +1 978-663-3660 x1479 - E: joshua.young[.]bruker.com.

 
 
Your Banner Ad Here instead - Showing along with ALL Articles covering Electronics/Instrumentation/RFID Announcements

Replace these Affiliate Programs at ANYTIME! Your banner here within the next hour. Learn How!


 

Written by / Agency / Source: Bruker Corporation

 
 

Availability: All Regions (Including Int'l)

 

Traffic Booster: [/] Quick Newswire Today Visibility Checker

 

Distribution / Indexing: [+] / [Company listed above is a registered member of our network. Content made possible by PRZOOM / PRTODAY indexing services]

 
 
# # #
 
 
  Your Banner Ad showing on ALL
Electronics/Instrumentation/RFID articles,
CATCH Visitors via Your Competitors Announcements!


World’s Highest Field 21 Tesla Magnet for FT-ICR Mass Spectrometry Installed at National High Magnetic Field Laboratory (NHMFL)

Company website links NOT available to basic submissions
It is OK to republish and/or LINK any newswire for any legitimate media purpose as long as you name Newswire Today and LINK as the source.
 
  Is this your article?
Activate ALL web links and social stream by Upgrading to Press Release PREMIUM Plan Now!

Bruker Corporation | FT-ICR
Publisher Contact: Tony Lewtas - Bruker.com 
978 663 3660 x1212 tony.lewtas[.]bruker.com
 
Newswire Today - PRZOOM / PRTODAY disclaims any content contained in this article. If you need/wish to contact the company who published the current release, you will need to contact them - NOT us. Issuers of articles are solely responsible for the accuracy of their content. Our complete disclaimer appears here.
IMPORTANT INFORMATION: Issuance, publication or distribution of this press release in certain jurisdictions could be subject to restrictions. The recipient of this press release is responsible for using this press release and the information herein in accordance with the applicable rules and regulations in the particular jurisdiction. This press release does not constitute an offer or an offering to acquire or subscribe for any Bruker Corporation securities in any jurisdiction including any other companies listed or named in this release.

Electronics/Instrumentation/RFID via RSSAdd NewswireToday - PRZOOM Headline News to FeedBurner
Find who RetweetFollow @NewswireTODAY



Are you the owner of this article?, Turn it PREMIUM with your LOGO instead - and make it 3rd party Ads-Free! within the next hour!


Read Latest Articles From Bruker Corporation / Company Profile


Read Electronics/Instrumentation/RFID Most Recent Related Newswires:

The Latest Beta LaserMike In-Process Measurement and Quality Cable Testing Solutions at Interwire 2017
Infineon Joins GSMA - Security and Broadband Expertise for Mobile Industry
Smart Electricity Meters - Europe Emerges as Key Regional Market Finds Frost & Sullivan
NI Announces the Next Generation of USRP RIO Software Defined Radio Solutions for Design, Prototyping and Deployment
GE Ventures and Samsung Electro-Mechanics Announce Global Microelectronics Packaging Patent Agreement
Curtiss-Wright Introduces Space Industry's First Low-Cost COTS Module for Measuring Microgravity Acceleration
Curtiss-Wright Debuts Stackable Analog Video Switch for Defense and Aerospace Platforms
Micro Oscillator, Inc. Releases Wireless 5uA Inductive Proximity Sensor RF System
Strong Growth Opportunities Emerge in Southeast Asian Printed Electronics Market Finds Frost & Sullivan
Cannon Wins Top Honors from Frost & Sullivan for Dominating the Global Modular Data Centers Market with its Visionary Product Development Strategies
NDC Technologies Introduces Non-Contact Eccentricity Gauge Keeps Cable Core Centered, Improves Product Quality and Delivers Production Savings
Curtiss-Wright Selected by ELV to Provide Cost-Effective Telemetry System for the European Space Agency's New Vega-C Launcher
Spectris Plc Acquires Pixirad Srl
Bruker Introduces MALDI PharmaPulse™ 2.0 Solution at SLAS 2017 for 100x Faster Mass Spectrometry-Based, Label-Free Screening in Drug Discovery
GUC Unveils Solid State Drive ASIC Capabilities

Boost Your Social Network
& Crowdfunding Campaigns


LIFETIME SOCIAL MEDIA WALL
NewswireToday Celebrates 10 Years in Business


PREMIUM Members


Visit  BizJobs.com

Visit  JobsWare.com





 
  ©2017 Newswire Today — Limelon Advertising, Co.
Home | About | Advertise/Pricing | Contact | Investors | Privacy/TOS | Sitemap | FRANCAIS
newswire, PR free press releases distribution service magazines engine news alert newsroom press room breaking news public relations articles company news alerts newswiredistribution ezine bizentrepreneur biznewstoday digital business report market search pr firms agencies reports distri-bution today investor relation successful internet entrepreneurs newswire distribution prtoday.com freenewswiredistribution asianewstoday bizwiretoday USA pr UK today - NOT affiliated with PRNewswire as we declined their partnership offer in 2013
 
PRTODAY & NewswireTODAY are NOT affiliated with USA TODAY (usatoday.com)